Features• 1.65"x 0.88" compact size• Medical safety approved (2x MOPP) according to ANSI/AMMI ES60601-1 and IEC/BS EN/EN60601-1• Suitable for BF application with appropriate system consideration• No load power consumption < 0.075W• Extremely low leakage current• Wide operation temperature range -40 ~ +85℃• EMI class B for class II configuration• Protections: Short circuit / Overload / Over voltage /over temperature• No minimum load required• Typical lifetime > 52K Hours• 2 years warranty
Features• 1.65"x 0.88" compact size• Medical safety approved (2x MOPP) according to ANSI/AMMI ES60601-1 and IEC/BS EN/EN60601-1• Suitable for BF application with appropriate system consideration• No load power consumption < 0.075W• Extremely low leakage current• Wide operation temperature range -30 ~ +85℃• EMI class B for class II configuration• Protections: Short circuit / Overload / Over voltage /over temperature• No minimum load required• 2 years warranty
Features• 1.93"x 0.94" compact size• Medical safety approved (2x MOPP) according to ANSI/AMMI ES60601-1 and IEC60601-1• Suitable for BF application with appropriate system consideration• No load power consumption < 0.1W• Extremely low leakage current• Wide operation temperature range -35 ~ +85℃• EMI class B for class II configuration• Protections: Short circuit / Overload / Over voltage /over temperature• No minimum load required• 2 years warranty
Features• 4" x 2" compact size• Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1• Suitable for BF application with appropriate system consideration• Cooling by free air convection• EMI Class B for class I configuration• Extremely low leakage current• Protections: Short circuit / Overload / Over voltage• 2 years warranty
Features• 5"x 3" compact size• Medical safety approved (2x MOPP) according to ANSI/AMMI ES60601-1, IEC/BS EN/EN60601-1• Suitable for BF application with appropriate system consideration• 100W convection, 145W force air• EMI class B for class I configuration• No load power consumption< 0.75W by PS-ON conrol(G model)• Extremely low leakage current• 5Vdc standby output, Power Good, Power Fail • Protections: Short circuit /Overload /Over voltage/Over temperature• Lifetime > 85K hours• 2 years warranty
Features• 2.58"x 1.38" compact size• Medical safety approved (2x MOPP) according to ANSI/AMMI ES60601-1 and IEC/BS EN/EN60601-1• Suitable for BF application with appropriate system consideration• No load power consumption < 0.075W• Extremely low leakage current• Wide operation temperature range -40 ~ +85℃• EMI class B for class II configuration• Protections: Short circuit / Overload / Over voltage• No minimum load required• 2 years warranty
Features• 4"x 2" compact size• IT & Medical safety approved (2x MOPP) according to ANSI/AMMI ES60601-1, IEC/BS EN/EN60601-1 and IEC/BS/EN/UL62368-1• Suitable for BF application with appropriate system consideration• Cooling by free air convection• EMI class B for class I configuration• No load power consumption < 0.75W• Protections: Short circuit / Overload / Over voltage• Operating altitude up to 3000 meters• 2 years warranty
Features• 5"x 2" compact size• Medical safety approved (2x MOPP) according to ANSI/AMMI ES60601-1, IEC/BS EN/EN60601-1 and IEC/BS/EN/UL62368-1• Suitable for BF application with appropriate system consideration• 72W convection, 100W force air• EMI class B for class I configuration• Extremely low leakage current• Protections: Short circuit / Overload / Over voltage• Lifetime > 140K hours• 2 years warranty
Features• 5"x 3" compact size• Medical safety approved (2x MOPP) according to ANSI/AMMI ES60601-1 and IEC/BS EN/EN60601-1• Suitable for BF application with appropriate system consideration• 110W convention, 160W force air• EMI class B for class II configuration• No load power consumption under 0.5W by PS-ON control (G model) • 5Vdc standby output, Power Good, Power Fail; Remote sense for 5 ~15V• Protections: Short circuit / Overload / Over voltage /over temperature• Operating altitude up to 3000 meters• 2 years warranty
Features• Universal AC input /Full range• Medical safety approved (2x MOPP) according to ANSI/AMMI ES60601-1, IEC/BS EN/EN60601-1• Free air convection for 140W and forced air convection for 200W• With power good and fail signal output• Built-in remote sense function• Built-in remote ON-OFF control• Extremely low leakage current< 180uA • Protections: Short circuit /Overload /Over voltage/Over temperature• Fixed switching frequency at 100KHz• 2 years warranty
Features• 4"x 2" compact size• Medical safety approved (2x MOPP) according to ANSI/AMMI ES60601-1 and IEC/BS EN/EN60601-1• Suitable for BF application with appropriate system consideration• 140W convention, 200W force air• EMI Conduction for Class B Radiation for class B with FG (Class I)and Class A without FG(Class II)• No load power consumption under 0.5W• Extremely low leakage current • Protections: Short circuit / Overload / Over voltage /over temperature• Lifetime> 65K hours• Operating altitude up to 5000 meters• 2 years warranty
Features• 5"x 3" compact size• Medical safety approved (2x MOPP) according to ANSI/AMMI ES60601-1 and IEC/BS EN/EN60601-1• Suitable for BF application with appropriate system consideration• 200W convention, 300W force air• No load power consumption < 0.5W by PS-ON control• Extremely low leakage current • 5Vdc standby output, 12Vdc fan supply, Power Good, Power Fail and remote sense• Protections: Short circuit / Overload / Over voltage /over temperature• Lifetime> 40K hours• 2 years warranty